Network Working Group C.M. Heard, Ed.
Request for Comments: 3637 Consultant
Category: Standards Track September 2003
Definitions of Managed Objects
for the Ethernet WAN Interface Sublayer
Status of this Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Copyright Notice
Copyright (C) The Internet Society (2003). All Rights Reserved.
Abstract
This document defines a portion of the Management Information Base
(MIB) for use with network management protocols in TCP/IP based
internets. In particular, it defines objects for managing the
Ethernet Wide Area Network (WAN) Interface Sublayer (WIS).
The MIB module defined in this memo is an extension of the
Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH)
Interface MIB and is implemented in conjunction with it and with the
Ethernet-like Interface MIB, the 802.3 Medium Attachment Unit MIB,
the Interfaces Group MIB, and the Inverted Stack Table MIB.
Table of Contents
1. Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . 2
2. The Internet-Standard Management Framework . . . . . . . . . . 2
3. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.1. Relationship to the SONET/SDH Interface MIB. . . . . . . 3
3.2. Relationship to the Ethernet-like Interface MIB. . . . . 4
3.3. Relationship to the 802.3 MAU MIB. . . . . . . . . . . . 4
3.4. Use of the ifTable . . . . . . . . . . . . . . . . . . . 4
3.4.1. Layering Model . . . . . . . . . . . . . . . . . 5
3.4.2. Use of ifTable for LLC Layer/MAC Layer
Reconciliation Sublayer/Physical Coding Sublayer 5
3.4.3. Use of ifTable for SONET/SDH Path Layer. . . . . 5
3.4.4. Use of ifTable for SONET/SDH Medium/Section/
Line Layer . . . . . . . . . . . . . . . . . . . 5
Heard Standards Track [Page 1]
RFC 3637 Ethernet WIS Objects September 2003
3.5. SONET/SDH Terminology. . . . . . . . . . . . . . . . . . 6
3.6. Mapping of IEEE 802.3 Managed Objects. . . . . . . . . . 7
3.7. Mapping of SNMP Objects to WIS Station Management
Registers. . . . . . . . . . . . . . . . . . . . . . . . 12
3.8. Structure of the MIB Module . . . . . . . . . . . . . . 14
3.8.1. etherWisDeviceTable. . . . . . . . . . . . . . . 14
3.8.2. etherWisSectionCurrentTable. . . . . . . . . . . 15
3.8.3. etherWisPathCurrentTable . . . . . . . . . . . . 15
3.8.4. etherWisFarEndPathCurrentTable . . . . . . . . . 15
4. Object Definitions . . . . . . . . . . . . . . . . . . . . . . 16
5. Intellectual Property Statement. . . . . . . . . . . . . . . . 30
6. Acknowledgments. . . . . . . . . . . . . . . . . . . . . . . . 30
7. Security Considerations. . . . . . . . . . . . . . . . . . . . 31
8. References . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.1. Normative References . . . . . . . . . . . . . . . . . . 32
8.2. Informative References . . . . . . . . . . . . . . . . . 33
Appendix A: Collection of Performance Data Using WIS
MDIO Registers . . . . . . . . . . . . . . . . . . . . . . . . 34
Contributors . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Editor's Address . . . . . . . . . . . . . . . . . . . . . . . . . 36
Full Copyright Statement . . . . . . . . . . . . . . . . . . . . . 37
1. Conventions
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
"OPTIONAL", when they appear in this document, are to be interpreted
as described in BCP 14, RFC 2119 [RFC2119].
2. The Internet-Standard Management Framework
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to section 7 of
RFC 3410 [RFC3410].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. MIB objects are generally
accessed through the Simple Network Management Protocol (SNMP).
Objects in the MIB are defined using the mechanisms defined in the
Structure of Management Information (SMI). This memo specifies a MIB
module that is compliant to the SMIv2, which is described in STD 58,
RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
[RFC2580].
Heard Standards Track [Page 2]
RFC 3637 Ethernet WIS Objects September 2003
3. Overview
The objects defined in this memo are used in conjunction with objects
defined in the Interfaces Group MIB [RFC2863], the SONET/SDH
Interface MIB [RFC3592], and the 802.3 MAU MIB [RFC3636] to manage
the Ethernet Wide Area Network (WAN) Interface Sublayer (WIS) defined
in [802.3ae]. The WIS contains functions to perform OC-192c/VC-4-64c
framing and scrambling. It resides between the Physical Coding
Sublayer (PCS) and the Physical Medium Attachment (PMA) sublayer
within a 10GBASE-W 10 Gb/s WAN-compatible physical layer device (PHY)
and may be used in conjunction with any of the PCS, PMA, and Physical
Medium Dependent (PMD) sublayers defined in [802.3ae] for 10GBASE-W
PHYs. Three types of 10GBASE-W PHYs are defined, distinguished by
the type of optics employed: 10GBASE-SW, 10GBASE-LW, and 10GBASE-EW.
The objects defined in this memo may be used to manage an Ethernet
interface employing any type of 10GBASE-W PHY. They do not apply to
any other kind of interface. In particular, they do not apply to
so-called Ethernet Line Terminating Equipment (ELTE) residing within
a SONET network element that uses the 10GBASE-W PMA/PMD sublayers but
otherwise acts as SONET Line Terminating Equipment (LTE).
The objects presented here -- along with those incorporated by
reference from the Interfaces Group MIB, the SONET/SDH Interface MIB,
and the 802.3 MAU MIB -- are intended to provide exact
representations of the mandatory attributes in the oWIS managed
object class (i.e., the members of the pWISBasic package) defined in
Clause 30 and Annex 30A of [802.3ae]. They are also intended to
provide approximate representations of the optional attributes (i.e.,
the members of the pWISOptional package). Some objects with no
analogues in oWIS are defined to support WIS testing features
required by Clause 50 of [802.3ae].
3.1. Relationship to the SONET/SDH Interface MIB
Since the Ethernet WAN Interface Sublayer was designed to be SONET-
compatible, information similar to that provided by most of the
members of the oWIS managed object class is available from objects
defined in the SONET-MIB [RFC3592]. Thus, the MIB module defined in
this memo is a sparse augmentation of the SONET-MIB -- in other
words, every table defined here is an extension of some table in the
SONET-MIB -- and its compliance statement REQUIRES that an agent
implementing the objects defined in this memo also implement the
relevant SONET-MIB objects. That includes all objects required by
sonetCompliance2 as well as some that it leaves optional.
It should be noted that some of the objects incorporated by reference
from the SONET-MIB -- specifically, the threshold objects and
interval counter objects -- provide only approximate representations
Heard Standards Track [Page 3]
RFC 3637 Ethernet WIS Objects September 2003
of the corresponding oWIS attributes, as detailed in Section 3.6. An
alternative approach would have been to define new objects to exactly
match the oWIS definitions. That approach was rejected because the
SONET-MIB objects are already used in deployed systems to manage the
SONET sublayers of ATM over SONET and PPP over SONET interfaces, and
it was deemed undesirable to use a different scheme to manage the
SONET sublayers of 10 Gb/s WAN-compatible Ethernet interfaces. Note
that the approach adopted by this memo requires no hardware support
beyond that mandated by [802.3ae] subclause 50.3.11.
3.2. Relationship to the Ethernet-like Interface MIB
An interface which includes the Ethernet WIS is, by definition, an
Ethernet-like interface, and an agent implementing the objects
defined in this memo MUST implement the objects required by the
dot3Compliance2 compliance statement in the EtherLike-MIB.
3.3. Relationship to the 802.3 MAU MIB
Support for the mauModIfCompl3 compliance statement of the MAU-MIB
[RFC3636] is REQUIRED for all Ethernet-like interfaces. The MAU-MIB
is needed in order to allow applications to control and/or determine
the media type in use. That is important for devices than can
support both the 10GBASE-R 10 Gb/s LAN format (which does not include
the WIS) and the 10GBASE-W 10 Gb/s WAN format (which does include the
WIS). The MAU-MIB also provides the means to put a device in standby
mode or to reset it; the latter may be used to re-initialize the
WIS.
3.4. Use of the ifTable
This section specifies how the ifTable, as defined in [RFC2863], is
used for the Ethernet WIS application.
Heard Standards Track [Page 4]
RFC 3637 Ethernet WIS Objects September 2003
3.4.1. Layering Model
Ethernet interfaces that employ the WIS are layered as defined in
[802.3ae]. The corresponding use of the ifTable [RFC2863] is shown
in the figure below.
_____________________________ _
| LLC Layer | |
+-----------------------------+ |
| MAC Layer | |
+-----------------------------+ > 1 ifEntry
| Reconciliation Sublayer | | ifType: ethernetCsmacd(6)
+-----------------------------+ |
| Physical Coding Sublayer | |
+-----------------------------+ +
| Path Layer | > 1 ifEntry
+-----------------------------+ + ifType: sonetPath(50)
| Line Layer | |
+-----------------------------+ |
| Section Layer | > 1 ifEntry
+-----------------------------+ | ifType: sonet(39)
| Physical Medium Layer | |
----------------------------- -
Figure 1 - Use of ifTable for an Ethernet WIS port
The exact configuration and multiplexing of the layers is maintained
in the ifStackTable [RFC2863] and in the ifInvStackTable [RFC2864].
3.4.2. Use of ifTable for LLC Layer/MAC Layer/Reconciliation
Sublayer/Physical Coding Sublayer
The ifTable MUST be used as specified in [RFC3635] and [RFC3636] for
the LLC Layer/MAC Layer/Reconciliation Sublayer/Physical Coding
Sublayer.
3.4.3. Use of ifTable for SONET/SDH Path Layer
The ifTable MUST be used as specified in [RFC3592] for the SONET/SDH
Path Layer. The value of ifHighSpeed is set to 9585. ifSpeed
reports a value of 4294967295.
3.4.4. Use of ifTable for SONET/SDH Medium/Section/Line Layer
The ifTable MUST be used as specified in [RFC3592] for the SONET/SDH
Medium/Section/Line Layer. The value of ifHighSpeed is set to 9953.
ifSpeed reports a value of 4294967295.
Heard Standards Track [Page 5]
RFC 3637 Ethernet WIS Objects September 2003
3.5. SONET/SDH Terminology
The SONET/SDH terminology used in [802.3ae] is mostly the same as in
[RFC3592], but there are a few differences. In those cases the
definitions in [802.3ae] take precedence. The specific differences
are as follows.
Unequipped
This defect is not defined by [802.3ae]. An implementation that
supports it SHOULD report it by setting the sonetPathUnequipped
bit in the appropriate instance of sonetPathCurrentStatus.
Signal Label Mismatch
This defect is called Payload Label Mismatch (PLM) in [802.3ae].
It is reported by setting both the sonetPathSignalLabelMismatch
bit in the appropriate instance of sonetPathCurrentStatus
(defined in [RFC3592]) and the etherWisPathPLM bit in the
corresponding instance of etherWisPathCurrentStatus (defined
below).
Loss of Codegroup Delineation
[802.3ae] defines Loss of Codegroup Delineation (LCD) as
occurring when the Physical Coding Sublayer is unable to locate
64B/66B code group boundaries. There is no analogous defect
defined in [RFC3592]. It is reported by setting the
etherWisPathLCD bit in the appropriate instance of the object
etherWisPathCurrentStatus defined below.
STS-Path Remote Defect Indication
[802.3ae] mandates the use of ERDI-P (Enhanced Remote Defect
Indication - Path) defined in [T1.231] to signal remote server
defects (triggered by path AIS or path LOP) and remote payload
defects (triggered by Payload Label Mismatch or Loss of Codegroup
Delineation). [RFC3592] defines the one-bit RDI-P (Remote Defect
Indication - Path), which signals remote server detects (i.e.,
path AIS and path LOP) only. An implementation of the MIB module
defined in this memo MUST set the sonetPathSTSRDI bit in the
appropriate instance of sonetPathCurrentStatus when it receives
an ERDI-P server defect indication from the remote end. Both
ERDI-P payload defects and ERDI-P server defects are reported in
the object etherWisFarEndPathCurrentStatus defined below.
Heard Standards Track [Page 6]
RFC 3637 Ethernet WIS Objects September 2003
Path Coding Violations
In [802.3ae] the path layer CV count is based on block errors and
not BIP-8 errors, i.e., it is incremented only once for each B3
byte that indicates incorrect parity, regardless of the number of
bits in error. Note that Section 8.4.5.1 of [T1.231] allows
either path BIP-8 errors or path block errors to be used for the
path layer error count.
3.6. Mapping of IEEE 802.3 Managed Objects
This section contains the mapping between oWIS managed objects
defined in [802.3ae] and managed objects defined in this document and
in associated MIB modules, i.e., the IF-MIB [RFC2863], the SONET-MIB
[RFC3592], and the MAU-MIB [RFC3636].
IEEE 802.3 Managed Object Corresponding SNMP Object
oWIS - pWISBasic package
aWISID IF-MIB - ifIndex
aSectionStatus SONET-MIB - sonetSectionCurrentStatus
aLineStatus SONET-MIB - sonetLineCurrentStatus
aPathStatus etherWisPathCurrentStatus
aFarEndPathStatus etherWisFarEndPathCurrentStatus
oWIS - pWISOptional package
aSectionSESThreshold SONET-MIB - sonetSESthresholdSet
aSectionSESs SONET-MIB - sonetSectionCurrentSESs +
sonetSectionIntervalSESs
aSectionESs SONET-MIB - sonetSectionCurrentESs +
sonetSectionIntervalESs
aSectionSEFSs SONET-MIB - sonetSectionCurrentSEFSs +
sonetSectionIntervalSEFSs
aSectionCVs SONET-MIB - sonetSectionCurrentCVs +
sonetSectionIntervalCVs
aJ0ValueTX etherWisSectionCurrentJ0Transmitted
aJ0ValueRX etherWisSectionCurrentJ0Received
aLineSESThreshold SONET-MIB - sonetSESthresholdSet
aLineSESs SONET-MIB - sonetLineCurrentSESs +
sonetLineIntervalSESs
aLineESs SONET-MIB - sonetLineCurrentESs +
sonetLineIntervalESs
aLineCVs SONET-MIB - sonetLineCurrentCVs +
sonetLineIntervalCVs
aFarEndLineSESs SONET-MIB - sonetFarEndLineCurrentSESs +
sonetFarEndLineIntervalSESs
aFarEndLineESs SONET-MIB - sonetFarEndLineCurrentESs +
sonetFarEndLineIntervalESs
aFarEndLineCVs SONET-MIB - sonetFarEndLineCurrentCVs +
Heard Standards Track [Page 7]
RFC 3637 Ethernet WIS Objects September 2003
sonetFarEndLineIntervalCVs
aPathSESThreshold SONET-MIB - sonetSESthresholdSet
aPathSESs SONET-MIB - sonetPathCurrentSESs +
sonetPathIntervalSESs
aPathESs SONET-MIB - sonetPathCurrentESs +
sonetPathIntervalESs
aPathCVs SONET-MIB - sonetPathCurrentCVs +
sonetPathIntervalCVs
aJ1ValueTX etherWisPathCurrentJ1Transmitted
aJ1ValueRX etherWisPathCurrentJ1Received
aFarEndPathSESs SONET-MIB - sonetFarEndPathCurrentSESs +
sonetFarEndPathIntervalSESs
aFarEndPathESs SONET-MIB - sonetFarEndPathCurrentESs +
sonetFarEndPathIntervalESs
aFarEndPathCVs SONET-MIB - sonetFarEndPathCurrentCVs +
sonetFarEndPathIntervalCVs
It should be noted that the threshold and counter objects imported
from the SONET-MIB are not completely equivalent to the corresponding
IEEE 802.3 objects. The specific differences are as follows:
IEEE 802.3 Managed Object How Corresponding SNMP Object Differs
aSectionSESThreshold This object is defined in [802.3ae] as an
integer with one instance per interface.
sonetSESthresholdSet is an enumerated value
that has one instance per network element;
it controls the thresholds for all layers
simultaneously and allows only certain
discrete values to be selected.
aSectionSESs This object is defined in [802.3ae] as a
generalized nonresetable counter. The
objects sonetSectionCurrentSESs and
sonetSectionIntervalSESs are 15-minute
interval counters.
aSectionESs This object is defined as a generalized
nonresetable counter in [802.3ae]. The
objects sonetSectionCurrentESs and
sonetSectionIntervalESs are 15-minute
interval counters.
Heard Standards Track [Page 8]
RFC 3637 Ethernet WIS Objects September 2003
aSectionSEFSs This object is defined as a generalized
nonresetable counter in [802.3ae]. The
objects sonetSectionCurrentSEFSs and
sonetSectionIntervalSEFSs are 15-minute
interval counters.
aSectionCVs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
sonetSectionCurrentCVs and
sonetSectionIntervalCVs are 15-minute
interval counters, and they are inhibited
(not incremented) during one-second
intervals that qualify as severely errored
seconds.
aLineSESThreshold This object is defined in [802.3ae] as an
integer with one instance per interface.
sonetSESthresholdSet is an enumerated value
that has one instance per network element;
it controls the thresholds for all layers
simultaneously and allows only certain
discrete values to be selected.
aLineSESs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
sonetLineCurrentSESs and
sonetLineIntervalSESs are 15-minute
interval counters, and they are inhibited
(not incremented) during one-second
intervals that qualify as unavailable
seconds.
aLineESs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
sonetLineCurrentESs and
sonetLineIntervalESs are 15-minute interval
counters, and they are inhibited (not
incremented) during one-second intervals
that qualify as unavailable seconds.
aLineCVs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
sonetLineCurrentCVs and
sonetLineIntervalCVs are 15-minute interval
Heard Standards Track [Page 9]
RFC 3637 Ethernet WIS Objects September 2003
counters, and they are inhibited (not
incremented) during one-second intervals
that qualify either as severely errored
seconds or as unavailable seconds.
aFarEndLineSESs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
sonetFarEndLineCurrentSESs and
sonetFarEndLineIntervalSESs are 15-minute
interval counters, and they are inhibited
(not incremented) during one-second
intervals that qualify as unavailable
seconds.
aFarEndLineESs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
sonetFarEndLineCurrentESs and
sonetFarEndLineIntervalESs are 15-minute
interval counters, and they are inhibited
(not incremented) during one-second
intervals that qualify as unavailable
seconds.
aFarEndLineCVs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
sonetFarEndLineCurrentCVs and
sonetFarEndLineIntervalCVs are 15-minute
interval counters, and they are inhibited
(not incremented) during one-second
intervals that qualify either as severely
errored seconds or as unavailable seconds.
aPathSESThreshold This object is defined in [802.3ae] as an
integer with one instance per interface.
sonetSESthresholdSet is an enumerated value
that has one instance per network element;
it controls the thresholds for all layers
simultaneously and allows only certain
discrete values to be selected.
aPathSESs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
sonetPathCurrentSESs and
sonetPathIntervalSESs are 15-minute
Heard Standards Track [Page 10]
RFC 3637 Ethernet WIS Objects September 2003
interval counters, and they are inhibited
(not incremented) during one-second
intervals that qualify as unavailable
seconds. In addition, [802.3ae] includes
PLM-P and LCD-P defects in the criteria for
declaring path layer severely errored
seconds, while [RFC3592] does not.
aPathESs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
sonetPathCurrentESs and
sonetPathIntervalESs are 15-minute interval
counters, and they are inhibited (not
incremented) during one-second intervals
that qualify as unavailable seconds. In
addition, [802.3ae] includes PLM-P and
LCD-P defects in the criteria for declaring
path layer errored seconds, while [RFC3592]
does not.
aPathCVs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
sonetPathCurrentCVs and
sonetPathIntervalCVs are 15-minute interval
counters, and they are inhibited (not
incremented) during one-second intervals
that qualify either as severely errored
seconds or as unavailable seconds.
aFarEndPathSESs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
sonetFarEndPathCurrentSESs and
sonetFarEndPathIntervalSESs are 15-minute
interval counters, and they are inhibited
(not incremented) during one-second
intervals that qualify as unavailable
seconds. In addition, [802.3ae] includes
far-end PLM-P and LCD-P defects in the
criteria for declaring far-end path layer
severely errored seconds, while [RFC3592]
does not.
aFarEndPathESs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
Heard Standards Track [Page 11]
RFC 3637 Ethernet WIS Objects September 2003
sonetFarEndPathCurrentESs and
sonetFarEndPathIntervalESs are 15-minute
interval counters, and they are inhibited
(not incremented) during one-second
intervals that qualify as unavailable
seconds. In addition, [802.3ae] includes
far-end PLM-P and LCD-P defects in the
criteria for declaring far-end path layer
errored seconds, while [RFC3592] does not.
aFarEndPathCVs This object is defined as a generalized
nonresetable counter in [802.3ae], and it
is not subject to inhibiting. The objects
sonetFarEndPathCurrentCVs and
sonetFarEndPathIntervalCVs are 15-minute
interval counters, and they are inhibited
(not incremented) during one-second
intervals that qualify either as severely
errored seconds or as unavailable seconds.
Note: despite the semantic differences between the threshold objects
and counter objects imported from the SONET-MIB and the corresponding
IEEE 802.3 objects, the hardware support mandated by [802.3ae]
subclause 50.3.11 suffices for both. See Appendix A for details.
3.7. Mapping of SNMP Objects to WIS Station Management Registers
Some of the objects defined in this memo or incorporated by reference
from the SONET-MIB [RFC3592] or the MAU-MIB [RFC3636] require
WIS-specific hardware support. [802.3ae] subclause 50.3.11 specifies
WIS management interface requirements, including a required subset of
the WIS Management Data Input/Output (MDIO) registers defined in
[802.3ae] subclause 45.2.2. The table below provides a cross-
reference between those managed objects and the WIS MDIO registers
from the subset in [802.3ae] subclause 50.3.11 required to support
them. Note that the MDIO interface is optional; however, if it is
not implemented, then the capabilities of the required register
subset must be provided by other means.
SNMP Object WIS MDIO Register(s)
ETHER-WIS - etherWisDeviceTxTestPatternMode 10G WIS control 2
ETHER-WIS - etherWisDeviceRxTestPatternMode 10G WIS control 2
ETHER-WIS - etherWisDeviceRxTestPatternErrors 10G WIS test pattern
error counter
SONET-MIB - sonetMediumType none required
SONET-MIB - sonetMediumTimeElapsed none required
Heard Standards Track [Page 12]
RFC 3637 Ethernet WIS Objects September 2003
SONET-MIB - sonetMediumValidIntervals none required
SONET-MIB - sonetMediumLineCoding none required
SONET-MIB - sonetMediumLineType none required
SONET-MIB - sonetMediumCircuitIdentifier none required
SONET-MIB - sonetMediumInvalidIntervals none required
SONET-MIB - sonetMediumLoopbackConfig none required
SONET-MIB - sonetSESthresholdSet none required
ETHER-WIS - etherWisSectionCurrentJ0Transmitted 10G WIS J0 transmit
ETHER-WIS - etherWisSectionCurrentJ0Received 10G WIS J0 receive
SONET-MIB - sonetSectionCurrentStatus 10G WIS status 3
SONET-MIB - sonetSectionCurrentESs \
SONET-MIB - sonetSectionCurrentSESs \
SONET-MIB - sonetSectionCurrentSEFSs | 10G WIS status 3
SONET-MIB - sonetSectionCurrentCVs | +
SONET-MIB - sonetSectionIntervalESs | 10G WIS section
SONET-MIB - sonetSectionIntervalSESs | BIP error count
SONET-MIB - sonetSectionIntervalSEFSs /
SONET-MIB - sonetSectionIntervalCVs /
SONET-MIB - sonetSectionIntervalValidData none required
SONET-MIB - sonetLineCurrentStatus 10G WIS status 3
SONET-MIB - sonetLineCurrentESs \
SONET-MIB - sonetLineCurrentSESs \
SONET-MIB - sonetLineCurrentCVs | 10G WIS status 3
SONET-MIB - sonetLineCurrentUASs | +
SONET-MIB - sonetLineIntervalESs | 10G WIS line
SONET-MIB - sonetLineIntervalSESs | BIP errors
SONET-MIB - sonetLineIntervalCVs /
SONET-MIB - sonetLineIntervalUASs /
SONET-MIB - sonetLineIntervalValidData none required
SONET-MIB - sonetFarEndLineCurrentESs \
SONET-MIB - sonetFarEndLineCurrentSESs \
SONET-MIB - sonetFarEndLineCurrentCVs | 10G WIS status 3
SONET-MIB - sonetFarEndLineCurrentUASs | +
SONET-MIB - sonetFarEndLineIntervalESs | 10G WIS far end
SONET-MIB - sonetFarEndLineIntervalSESs | line BIP errors
SONET-MIB - sonetFarEndLineIntervalCVs /
SONET-MIB - sonetFarEndLineIntervalUASs /
SONET-MIB - sonetFarEndLineIntervalValidData 10G WIS status 3
ETHER-WIS - etherWisPathCurrentStatus 10G WIS status 3
ETHER-WIS - etherWisPathCurrentJ1Transmitted 10G WIS J1 transmit
ETHER-WIS - etherWisPathCurrentJ1Received 10G WIS J1 receive
SONET-MIB - sonetPathCurrentWidth none required
SONET-MIB - sonetPathCurrentStatus 10G WIS status 3
Heard Standards Track [Page 13]
RFC 3637 Ethernet WIS Objects September 2003
SONET-MIB - sonetPathCurrentESs \
SONET-MIB - sonetPathCurrentSESs \
SONET-MIB - sonetPathCurrentCVs | 10G WIS status 3
SONET-MIB - sonetPathCurrentUASs | +
SONET-MIB - sonetPathIntervalESs | 10G WIS
SONET-MIB - sonetPathIntervalSESs | path block
SONET-MIB - sonetPathIntervalCVs / error count
SONET-MIB - sonetPathIntervalUASs /
SONET-MIB - sonetPathIntervalValidData none required
ETHER-WIS - etherWisFarEndPathCurrentStatus 10G WIS status 3
SONET-MIB - sonetFarEndPathCurrentESs \
SONET-MIB - sonetFarEndPathCurrentSESs \
SONET-MIB - sonetFarEndPathCurrentCVs | 10G WIS status 3
SONET-MIB - sonetFarEndPathCurrentUASs | +
SONET-MIB - sonetFarEndPathIntervalESs | 10G WIS far end
SONET-MIB - sonetFarEndPathIntervalSESs | path block
SONET-MIB - sonetFarEndPathIntervalCVs / error count
SONET-MIB - sonetFarEndPathIntervalUASs /
SONET-MIB - sonetFarEndPathIntervalValidData 10G WIS status 3
MAU-MIB - ifMauIfIndex none required
MAU-MIB - ifMauIndex none required
MAU-MIB - ifMauType 10G WIS control 2
MAU-MIB - ifMauStatus WIS control 1
MAU-MIB - ifMauMediaAvailable \ WIS status 1 +
MAU-MIB - ifMauMediaAvailableStateExits / 10G WIS status 3
MAU-MIB - ifMauJabberState none required
MAU-MIB - ifMauJabberingStateEnters none required
MAU-MIB - ifMauFalseCarriers none required
MAU-MIB - ifMauDefaultType 10G WIS control 2
MAU-MIB - ifMauAutoNegSupported none required
MAU-MIB - ifMauTypeListBits 10G WIS status 2
3.8. Structure of the MIB Module
Four tables are defined in this MIB module.
3.8.1. etherWisDeviceTable
The purpose of this table is to define managed objects to control the
WIS test pattern mode. These objects are required to support
mandatory and optional WIS test features specified in [802.3ae]
subclause 50.3.8.
Heard Standards Track [Page 14]
RFC 3637 Ethernet WIS Objects September 2003
The etherWisDeviceTable is a sparse augmentation of the
sonetMediumTable of the SONET-MIB -- in other words, for each entry
in the etherWisDeviceTable there MUST be an entry in the
sonetMediumTable and the same ifIndex value MUST be used for both
entries.
3.8.2. etherWisSectionCurrentTable
The purpose of this table is to define managed objects for the
transmitted and received section trace messages (J0 byte).
The etherWisSectionCurrentTable is a sparse augmentation of the
sonetSectionCurrentTable of the SONET-MIB -- in other words, for each
entry in the etherWisSectionCurrentTable there MUST be an entry in
the sonetSectionCurrentTable and the same ifIndex value MUST be used
for both entries.
3.8.3. etherWisPathCurrentTable
The purpose of this table is to define managed objects for the
current WIS path layer status and for the transmitted and received
path trace messages (J1 byte). The path layer status object is
provided because the WIS supports some near-end path status
conditions that are not reported in sonetPathCurrentStatus.
The etherWisPathCurrentTable is a sparse augmentation of the
sonetPathCurrentTable of the SONET-MIB -- in other words, for each
entry in the etherWisPathCurrentTable there MUST be an entry in the
sonetPathCurrentTable and the same ifIndex value MUST be used for
both entries.
3.8.4. etherWisFarEndPathCurrentTable
The purpose of this table is to define a managed object for the
current status of the far end of the path. This object is provided
because the WIS supports some far-end path status conditions that are
not reported in sonetPathCurrentStatus.
The etherWisFarEndPathCurrentTable is a sparse augmentation of the
sonetFarEndPathCurrentTable of the SONET-MIB -- in other words, for
each entry in the etherWisFarEndPathCurrentTable there MUST be an
entry in the sonetFarEndPathCurrentTable and the same ifIndex value
MUST be used for both entries.
Heard Standards Track [Page 15]
RFC 3637 Ethernet WIS Objects September 2003
4. Object Definitions
ETHER-WIS DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Gauge32, transmission
FROM SNMPv2-SMI
ifIndex
FROM IF-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
sonetMediumStuff2, sonetSectionStuff2,
sonetLineStuff2, sonetFarEndLineStuff2,
sonetPathStuff2, sonetFarEndPathStuff2,
sonetMediumType, sonetMediumLineCoding,
sonetMediumLineType, sonetMediumCircuitIdentifier,
sonetMediumLoopbackConfig, sonetSESthresholdSet,
sonetPathCurrentWidth
FROM SONET-MIB;
etherWisMIB MODULE-IDENTITY
LAST-UPDATED "200309190000Z" -- September 19, 2003
ORGANIZATION "IETF Ethernet Interfaces and Hub MIB
Working Group"
CONTACT-INFO
"WG charter:
http://www.ietf.org/html.charters/hubmib-charter.html
Mailing Lists:
General Discussion: hubmib@ietf.org
To Subscribe: hubmib-request@ietf.org
In Body: subscribe your_email_address
Chair: Dan Romascanu
Postal: Avaya Inc.
Atidim Technology Park, Bldg. 3
Tel Aviv 61131
Israel
Tel: +972 3 645 8414
E-mail: dromasca@avaya.com
Editor: C. M. Heard
Postal: 600 Rainbow Dr. #141
Mountain View, CA 94041-2542
USA
Tel: +1 650-964-8391
E-mail: heard@pobox.com"
Heard Standards Track [Page 16]
RFC 3637 Ethernet WIS Objects September 2003
DESCRIPTION
"The objects in this MIB module are used in conjunction
with objects in the SONET-MIB and the MAU-MIB to manage
the Ethernet WAN Interface Sublayer (WIS).
The following reference is used throughout this MIB module:
[IEEE 802.3 Std] refers to:
IEEE Std 802.3, 2000 Edition: 'IEEE Standard for
Information technology - Telecommunications and
information exchange between systems - Local and
metropolitan area networks - Specific requirements -
Part 3: Carrier sense multiple access with collision
detection (CSMA/CD) access method and physical layer
specifications', as amended by IEEE Std 802.3ae-2002,
'IEEE Standard for Carrier Sense Multiple Access with
Collision Detection (CSMA/CD) Access Method and
Physical Layer Specifications - Media Access Control
(MAC) Parameters, Physical Layer and Management
Parameters for 10 Gb/s Operation', 30 August 2002.
Of particular interest are Clause 50, 'WAN Interface
Sublayer (WIS), type 10GBASE-W', Clause 30, '10Mb/s,
100Mb/s, 1000Mb/s, and 10Gb/s MAC Control, and Link
Aggregation Management', and Clause 45, 'Management
Data Input/Output (MDIO) Interface'.
Copyright (C) The Internet Society (2003). This version
of this MIB module is part of RFC 3637; see the RFC
itself for full legal notices."
REVISION "200309190000Z" -- September 19, 2003
DESCRIPTION "Initial version, published as RFC 3637."
::= { transmission 134 }
-- The main sections of the module
etherWisObjects OBJECT IDENTIFIER ::= { etherWisMIB 1 }
etherWisObjectsPath OBJECT IDENTIFIER ::= { etherWisMIB 2 }
etherWisConformance OBJECT IDENTIFIER ::= { etherWisMIB 3 }
Heard Standards Track [Page 17]
RFC 3637 Ethernet WIS Objects September 2003
-- groups in the Ethernet WIS MIB module
etherWisDevice OBJECT IDENTIFIER ::= { etherWisObjects 1 }
etherWisSection OBJECT IDENTIFIER ::= { etherWisObjects 2 }
etherWisPath OBJECT IDENTIFIER ::= { etherWisObjectsPath 1 }
etherWisFarEndPath OBJECT IDENTIFIER ::= { etherWisObjectsPath 2 }
-- The Device group
-- These objects provide WIS extensions to
-- the SONET-MIB Medium Group.
etherWisDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherWisDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table for Ethernet WIS devices"
::= { etherWisDevice 1 }
etherWisDeviceEntry OBJECT-TYPE
SYNTAX EtherWisDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Ethernet WIS device table. For each
instance of this object there MUST be a corresponding
instance of sonetMediumEntry."
INDEX { ifIndex }
::= { etherWisDeviceTable 1 }
EtherWisDeviceEntry ::=
SEQUENCE {
etherWisDeviceTxTestPatternMode INTEGER,
etherWisDeviceRxTestPatternMode INTEGER,
etherWisDeviceRxTestPatternErrors Gauge32
}
Heard Standards Track [Page 18]
RFC 3637 Ethernet WIS Objects September 2003
etherWisDeviceTxTestPatternMode OBJECT-TYPE
SYNTAX INTEGER {
none(1),
squareWave(2),
prbs31(3),
mixedFrequency(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable controls the transmit test pattern mode.
The value none(1) puts the the WIS transmit path into
the normal operating mode. The value squareWave(2) puts
the WIS transmit path into the square wave test pattern
mode described in [IEEE 802.3 Std.] subclause 50.3.8.1.
The value prbs31(3) puts the WIS transmit path into the
PRBS31 test pattern mode described in [IEEE 802.3 Std.]
subclause 50.3.8.2. The value mixedFrequency(4) puts the
WIS transmit path into the mixed frequency test pattern
mode described in [IEEE 802.3 Std.] subclause 50.3.8.3.
Any attempt to set this object to a value other than
none(1) when the corresponding instance of ifAdminStatus
has the value up(1) MUST be rejected with the error
inconsistentValue, and any attempt to set the corresponding
instance of ifAdminStatus to the value up(1) when an
instance of this object has a value other than none(1)
MUST be rejected with the error inconsistentValue."
REFERENCE
"[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
checker, 45.2.2.6, 10G WIS control 2 register (2.7), and
45.2.2.7.2, PRBS31 pattern testing ability (2.8.1)."
::= { etherWisDeviceEntry 1 }
etherWisDeviceRxTestPatternMode OBJECT-TYPE
SYNTAX INTEGER {
none(1),
prbs31(3),
mixedFrequency(4)
}
MAX-ACCESS read-write
STATUS current
Heard Standards Track [Page 19]
RFC 3637 Ethernet WIS Objects September 2003
DESCRIPTION
"This variable controls the receive test pattern mode.
The value none(1) puts the the WIS receive path into the
normal operating mode. The value prbs31(3) puts the WIS
receive path into the PRBS31 test pattern mode described
in [IEEE 802.3 Std.] subclause 50.3.8.2. The value
mixedFrequency(4) puts the WIS receive path into the mixed
frequency test pattern mode described in [IEEE 802.3 Std.]
subclause 50.3.8.3. Any attempt to set this object to a
value other than none(1) when the corresponding instance
of ifAdminStatus has the value up(1) MUST be rejected with
the error inconsistentValue, and any attempt to set the
corresponding instance of ifAdminStatus to the value up(1)
when an instance of this object has a value other than
none(1) MUST be rejected with the error inconsistentValue."
REFERENCE
"[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
checker, 45.2.2.6, 10G WIS control 2 register (2.7), and
45.2.2.7.2, PRBS31 pattern testing ability (2.8.1)."
::= { etherWisDeviceEntry 2 }
etherWisDeviceRxTestPatternErrors OBJECT-TYPE
SYNTAX Gauge32 ( 0..65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object counts the number of errors detected when the
WIS receive path is operating in the PRBS31 test pattern
mode. It is reset to zero when the WIS receive path
initially enters that mode, and it increments each time
the PRBS pattern checker detects an error as described in
[IEEE 802.3 Std.] subclause 50.3.8.2 unless its value is
65535, in which case it remains unchanged. This object is
writeable so that it may be reset upon explicit request
of a command generator application while the WIS receive
path continues to operate in PRBS31 test pattern mode."
REFERENCE
"[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
checker, 45.2.2.7.2, PRBS31 pattern testing ability
(2.8.1), and 45.2.2.8, 10G WIS test pattern error counter
register (2.9)."
::= { etherWisDeviceEntry 3 }
Heard Standards Track [Page 20]
RFC 3637 Ethernet WIS Objects September 2003
-- The Section group
-- These objects provide WIS extensions to
-- the SONET-MIB Section Group.
etherWisSectionCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherWisSectionCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table for the current state of Ethernet WIS sections."
::= { etherWisSection 1 }
etherWisSectionCurrentEntry OBJECT-TYPE
SYNTAX EtherWisSectionCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the etherWisSectionCurrentTable. For each
instance of this object there MUST be a corresponding
instance of sonetSectionCurrentEntry."
INDEX { ifIndex }
::= { etherWisSectionCurrentTable 1 }
EtherWisSectionCurrentEntry ::=
SEQUENCE {
etherWisSectionCurrentJ0Transmitted OCTET STRING,
etherWisSectionCurrentJ0Received OCTET STRING
}
etherWisSectionCurrentJ0Transmitted OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the 16-octet section trace message that
is transmitted in the J0 byte. The value SHOULD
be '89'h followed by fifteen octets of '00'h
(or some cyclic shift thereof) when the section
trace function is not used, and the implementation
SHOULD use that value (or a cyclic shift thereof)
as a default if no other value has been set."
REFERENCE
"[IEEE 802.3 Std.], 30.8.1.1.8, aJ0ValueTX."
::= { etherWisSectionCurrentEntry 1 }
Heard Standards Track [Page 21]
RFC 3637 Ethernet WIS Objects September 2003
etherWisSectionCurrentJ0Received OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the 16-octet section trace message that
was most recently received in the J0 byte."
REFERENCE
"[IEEE 802.3 Std.], 30.8.1.1.9, aJ0ValueRX."
::= { etherWisSectionCurrentEntry 2 }
-- The Path group
-- These objects provide WIS extensions to
-- the SONET-MIB Path Group.
etherWisPathCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherWisPathCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table for the current state of Ethernet WIS paths."
::= { etherWisPath 1 }
etherWisPathCurrentEntry OBJECT-TYPE
SYNTAX EtherWisPathCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the etherWisPathCurrentTable. For each
instance of this object there MUST be a corresponding
instance of sonetPathCurrentEntry."
INDEX { ifIndex }
::= { etherWisPathCurrentTable 1 }
EtherWisPathCurrentEntry ::=
SEQUENCE {
etherWisPathCurrentStatus BITS,
etherWisPathCurrentJ1Transmitted OCTET STRING,
etherWisPathCurrentJ1Received OCTET STRING
}
Heard Standards Track [Page 22]
RFC 3637 Ethernet WIS Objects September 2003
etherWisPathCurrentStatus OBJECT-TYPE
SYNTAX BITS {
etherWisPathLOP(0),
etherWisPathAIS(1),
etherWisPathPLM(2),
etherWisPathLCD(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the current status of the
path payload with a bit map that can indicate multiple
defects at once. The bit positions are assigned as
follows:
etherWisPathLOP(0)
This bit is set to indicate that an
LOP-P (Loss of Pointer - Path) defect
is being experienced. Note: when this
bit is set, sonetPathSTSLOP MUST be set
in the corresponding instance of
sonetPathCurrentStatus.
etherWisPathAIS(1)
This bit is set to indicate that an
AIS-P (Alarm Indication Signal - Path)
defect is being experienced. Note: when
this bit is set, sonetPathSTSAIS MUST be
set in the corresponding instance of
sonetPathCurrentStatus.
etherWisPathPLM(1)
This bit is set to indicate that a
PLM-P (Payload Label Mismatch - Path)
defect is being experienced. Note: when
this bit is set, sonetPathSignalLabelMismatch
MUST be set in the corresponding instance of
sonetPathCurrentStatus.
Heard Standards Track [Page 23]
RFC 3637 Ethernet WIS Objects September 2003
etherWisPathLCD(3)
This bit is set to indicate that an
LCD-P (Loss of Codegroup Delination - Path)
defect is being experienced. Since this
defect is detected by the PCS and not by
the path layer itself, there is no
corresponding bit in sonetPathCurrentStatus."
REFERENCE
"[IEEE 802.3 Std.], 30.8.1.1.18, aPathStatus."
::= { etherWisPathCurrentEntry 1 }
etherWisPathCurrentJ1Transmitted OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the 16-octet path trace message that
is transmitted in the J1 byte. The value SHOULD
be '89'h followed by fifteen octets of '00'h
(or some cyclic shift thereof) when the path
trace function is not used, and the implementation
SHOULD use that value (or a cyclic shift thereof)
as a default if no other value has been set."
REFERENCE
"[IEEE 802.3 Std.], 30.8.1.1.23, aJ1ValueTX."
::= { etherWisPathCurrentEntry 2 }
etherWisPathCurrentJ1Received OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the 16-octet path trace message that
was most recently received in the J1 byte."
REFERENCE
"[IEEE 802.3 Std.], 30.8.1.1.24, aJ1ValueRX."
::= { etherWisPathCurrentEntry 3 }
Heard Standards Track [Page 24]
RFC 3637 Ethernet WIS Objects September 2003
-- The Far End Path group
-- These objects provide WIS extensions to
-- the SONET-MIB Far End Path Group.
etherWisFarEndPathCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherWisFarEndPathCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table for the current far-end state of Ethernet WIS
paths."
::= { etherWisFarEndPath 1 }
etherWisFarEndPathCurrentEntry OBJECT-TYPE
SYNTAX EtherWisFarEndPathCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the etherWisFarEndPathCurrentTable. For each
instance of this object there MUST be a corresponding
instance of sonetFarEndPathCurrentEntry."
INDEX { ifIndex }
::= { etherWisFarEndPathCurrentTable 1 }
EtherWisFarEndPathCurrentEntry ::=
SEQUENCE {
etherWisFarEndPathCurrentStatus BITS
}
etherWisFarEndPathCurrentStatus OBJECT-TYPE
SYNTAX BITS {
etherWisFarEndPayloadDefect(0),
etherWisFarEndServerDefect(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the current status at the
far end of the path using a bit map that can indicate
multiple defects at once. The bit positions are
assigned as follows:
etherWisFarEndPayloadDefect(0)
A far end payload defect (i.e., far end
PLM-P or LCD-P) is currently being signaled
in G1 bits 5-7.
Heard Standards Track [Page 25]
RFC 3637 Ethernet WIS Objects September 2003
etherWisFarEndServerDefect(1)
A far end server defect (i.e., far end
LOP-P or AIS-P) is currently being signaled
in G1 bits 5-7. Note: when this bit is set,
sonetPathSTSRDI MUST be set in the corresponding
instance of sonetPathCurrentStatus."
REFERENCE
"[IEEE 802.3 Std.], 30.8.1.1.25, aFarEndPathStatus."
::= { etherWisFarEndPathCurrentEntry 1 }
--
-- Conformance Statements
--
etherWisGroups OBJECT IDENTIFIER ::= { etherWisConformance 1 }
etherWisCompliances OBJECT IDENTIFIER ::= { etherWisConformance 2 }
-- Object Groups
etherWisDeviceGroupBasic OBJECT-GROUP
OBJECTS {
etherWisDeviceTxTestPatternMode,
etherWisDeviceRxTestPatternMode
}
STATUS current
DESCRIPTION
"A collection of objects that support test
features required of all WIS devices."
::= { etherWisGroups 1 }
etherWisDeviceGroupExtra OBJECT-GROUP
OBJECTS {
etherWisDeviceRxTestPatternErrors
}
STATUS current
DESCRIPTION
"A collection of objects that support
optional WIS device test features."
::= { etherWisGroups 2 }
Heard Standards Track [Page 26]
RFC 3637 Ethernet WIS Objects September 2003
etherWisSectionGroup OBJECT-GROUP
OBJECTS {
etherWisSectionCurrentJ0Transmitted,
etherWisSectionCurrentJ0Received
}
STATUS current
DESCRIPTION
"A collection of objects that provide
required information about a WIS section."
::= { etherWisGroups 3 }
etherWisPathGroup OBJECT-GROUP
OBJECTS {
etherWisPathCurrentStatus,
etherWisPathCurrentJ1Transmitted,
etherWisPathCurrentJ1Received
}
STATUS current
DESCRIPTION
"A collection of objects that provide
required information about a WIS path."
::= { etherWisGroups 4 }
etherWisFarEndPathGroup OBJECT-GROUP
OBJECTS {
etherWisFarEndPathCurrentStatus
}
STATUS current
DESCRIPTION
"A collection of objects that provide required
information about the far end of a WIS path."
::= { etherWisGroups 5 }
-- Compliance Statements
etherWisCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for interfaces that include
the Ethernet WIS. Compliance with the following
external compliance statements is prerequisite:
MIB Module Compliance Statement
---------- --------------------
IF-MIB ifCompliance3
IF-INVERTED-STACK-MIB ifInvCompliance
EtherLike-MIB dot3Compliance2
MAU-MIB mauModIfCompl3"
Heard Standards Track [Page 27]
RFC 3637 Ethernet WIS Objects September 2003
MODULE -- this module
MANDATORY-GROUPS {
etherWisDeviceGroupBasic,
etherWisSectionGroup,
etherWisPathGroup,
etherWisFarEndPathGroup
}
OBJECT etherWisDeviceTxTestPatternMode
SYNTAX INTEGER {
none(1),
squareWave(2),
mixedFrequency(4)
}
DESCRIPTION
"Support for values other than none(1),
squareWave(2), and mixedFrequency(4)
is not required."
OBJECT etherWisDeviceRxTestPatternMode
SYNTAX INTEGER {
none(1),
mixedFrequency(4)
}
DESCRIPTION
"Support for values other than none(1)
and mixedFrequency(4) is not required."
GROUP etherWisDeviceGroupExtra
DESCRIPTION
"Implementation of this group, along with support for
the value prbs31(3) for etherWisDeviceTxTestPatternMode
and etherWisDeviceRxTestPatternMode, is necessary if the
optional PRBS31 test pattern mode is to be supported."
OBJECT etherWisDeviceRxTestPatternErrors
WRITE-SYNTAX Gauge32 ( 0 )
DESCRIPTION
"An implementation is not required to
allow values other than zero to be
written to this object."
Heard Standards Track [Page 28]
RFC 3637 Ethernet WIS Objects September 2003
MODULE SONET-MIB
MANDATORY-GROUPS {
sonetMediumStuff2,
sonetSectionStuff2,
sonetLineStuff2,
sonetFarEndLineStuff2,
sonetPathStuff2,
sonetFarEndPathStuff2
}
OBJECT sonetMediumType
SYNTAX INTEGER {
sonet(1)
}
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, nor is support
for any value other than sonet(1)."
OBJECT sonetMediumLineCoding
SYNTAX INTEGER {
sonetMediumNRZ(4)
}
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, nor is support
for any value other than sonetMediumNRZ(4)."
OBJECT sonetMediumLineType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sonetMediumCircuitIdentifier
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sonetMediumLoopbackConfig
SYNTAX BITS {
sonetNoLoop(0),
sonetFacilityLoop(1)
}
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, nor is support for values
other than sonetNoLoop(0) and sonetFacilityLoop(1)."
Heard Standards Track [Page 29]
RFC 3637 Ethernet WIS Objects September 2003
OBJECT sonetSESthresholdSet
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one
of the enumerated values need be supported."
OBJECT sonetPathCurrentWidth
SYNTAX INTEGER {
sts192cSTM64(6)
}
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, nor is support
for any value other than sts192cSTM64(6)."
::= { etherWisCompliances 1 }
END
5. Intellectual Property Statement
The IETF takes no position regarding the validity or scope of any
intellectual property or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; neither does it represent that it
has made any effort to identify any such rights. Information on the
IETF's procedures with respect to rights in standards-track and
standards-related documentation can be found in BCP-11. Copies of
claims of rights made available for publication and any assurances of
licenses to be made available, or the result of an attempt made to
obtain a general license or permission for the use of such
proprietary rights by implementors or users of this specification can
be obtained from the IETF Secretariat.
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights which may cover technology that may be required to practice
this standard. Please address the information to the IETF Executive
Director.
6. Acknowledgments
This document is a product of the IETF Hub MIB and AToM MIB Working
Groups. It builds upon the work of the IEEE P802.3ae 10 Gigabit
Ethernet Task Force.
Heard Standards Track [Page 30]
RFC 3637 Ethernet WIS Objects September 2003
7. Security Considerations
There are five managed objects defined in this MIB module that have a
MAX-ACCESS clause of read-write: etherWisDeviceTxTestPatternMode,
etherWisDeviceRxTestPatternMode, etherWisDeviceRxTestPatternErrors,
etherWisSectionCurrentJ0Transmitted, and
etherWisPathCurrentJ1Transmitted. Writing to these objects can have
the following potentially disruptive effects on network operation:
o changing the transmit or receive test pattern mode or modifying
the accumulated error count from a PRBS31 pattern test on an
administratively disabled 10GBASE-W interface, which can
interfere with an in-progress pattern test;
o modifying the transmitted section trace and/or path trace
message on an operational 10GBASE-W interface, which can cause
connectivity alarms to be raised at the remote of the link.
The user of this MIB module must therefore be aware that support for
SET operations in a non-secure environment without proper protection
can have a negative effect on network operations.
The readable objects in this MIB module (i.e., those with MAX-ACCESS
other than not-accessible) may be considered sensitive in some
environments since, collectively, they provide information about the
performance of network interfaces and can reveal some aspects of
their configuration. In such environments it is important to control
even GET and NOTIFY access to these objects and possibly even to
encrypt their values when sending them over the network via SNMP.
SNMP versions prior to SNMPv3 did not include adequate security.
Even if the network itself is secure (for example by using IPSec),
even then, there is no control as to who on the secure network is
allowed to access and GET/SET (read/change/create/delete) the objects
in this MIB module.
It is RECOMMENDED that implementers consider the security features as
provided by the SNMPv3 framework (see [RFC3410], section 8),
including full support for the SNMPv3 cryptographic mechanisms (for
authentication and privacy).
Further, deployment of SNMP versions prior to SNMPv3 is NOT
RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of this MIB module is properly configured to give access to
the objects only to those principals (users) that have legitimate
rights to indeed GET or SET (change/create/delete) them.
Heard Standards Track [Page 31]
RFC 3637 Ethernet WIS Objects September 2003
8. References
8.1. Normative References
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirements Levels", BCP 14, RFC 2119, March 1997.
[RFC2578] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
Rose, M. and S. Waldbusser, "Structure of Management
Information Version 2 (SMIv2)", STD 58, RFC 2578, April
1999.
[RFC2579] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
Rose, M. and S. Waldbusser, "Textual Conventions for
SMIv2", STD 58, RFC 2579, April 1999.
[RFC2580] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
Rose, M. and S. Waldbusser, "Conformance Statements for
SMIv2", STD 58, RFC 2580, April 1999.
[RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces Group
MIB", RFC 2863, June 2000.
[RFC2864] McCloghrie, K. and G. Hanson, "The Inverted Stack Table
Extension to the Interfaces Group MIB", RFC 2864, June
2000.
[RFC3592] Tesink, K., "Definitions of Managed Objects for the
Synchronous Optical Network/Synchronous Digital Hierarchy
(SONET/SDH) Interface Type", RFC 3592, September 2003.
[T1.231] American National Standard for Telecommunications -
Digital Hierarchy - Layer 1 In-Service Digital
Transmission Performance Monitoring, ANSI T1.231-1997,
September 1997.
[RFC3635] Flick, J., "Definitions of Managed Objects for the
Ethernet-like Interface Types", RFC 3635, September 2003.
[RFC3636] Flick, J., "Definitions of Managed Objects for IEEE 802.3
Medium Attachment Units (MAUs)", RFC 3636, September
2003.
Heard Standards Track [Page 32]
RFC 3637 Ethernet WIS Objects September 2003
[802.3ae] Institute of Electrical and Electronic Engineers, IEEE
Std 802.3ae-2002, "IEEE Standard for Carrier Sense
Multiple Access with Collision Detection (CSMA/CD) Access
Method and Physical Layer Specifications - Media Access
Control (MAC) Parameters, Physical Layer and Management
Parameters for 10 Gb/s Operation", August 2002.
8.2. Informative References
[RFC3410] Case, J., Mundy, R., Partain, D. and B. Stewart,
"Introduction and Applicability Statements for Internet-
Standard Management Framework", RFC 3410, December 2002.
Heard Standards Track [Page 33]
RFC 3637 Ethernet WIS Objects September 2003
Appendix A: Collection of Performance Data Using WIS MDIO Registers
The purpose of this appendix is to illustrate how the WIS MDIO
registers specified in [802.3ae] subclause 45.2.2 (and more
specifically the subset required by [802.3ae] subclause 50.3.11) can
be used to collect performance data either according to the
conventions adopted by this document or according to the conventions
specified in [802.3ae] Clause 30.
For an agent implementing the SNMP managed objects required by this
document the first step in collecting WIS performance data would be
to poll the 10G WIS status 3 register and the various error count
registers (10G WIS section BIP error count, 10G WIS line BIP errors,
10G WIS far end line BIP errors, 10G WIS path block error count, and
10G WIS far end path block error count) once per second. The 10G WIS
status 3 register bits are all latched until read and so would
indicate whether a given defect occurred any time during the previous
second. The error count registers roll over modulo 2^16 or 2^32, and
so to find the number of errors within the previous second the agent
would need to subtract (modulo 2^16 or 2^32) the current reading from
the reading taken one second ago. Armed with that information, the
agent could determine for any layer whether the one second interval
was an errored second, a severely errored second (that requires
comparison with a threshold unless a defect is present), or a
severely errored frame second. Determining whether a given second is
or is not part of unavailable time requires additional logic; the
most straightforward and accurate method is the delay-line approach
outlined in Appendix A of [RFC3592]. With that information available
the agent would be able to determine by how much each current count
should be incremented (including effects of inhibiting).
Implementations that conform to [T1.231] would end each 15-minute
interval on time-of-day clock 1/4 hour boundaries; if the delay-line
approach is used then a time-of-day timestamp would accompany the
one-second statistics. At the end of each interval the current
registers would be pushed onto the history stack and then would be
cleared. The xyxIntervalValidData flags would be set to False(2) if
the number of samples was not between 890 and 910 or, in the case of
far-end counts, if a near-end defect occurred during the
just-completed interval (see [T1.231] Section 9.1.2.2 for details).
An agent implementing the [802.3ae] Clause 30 oWIS objects could also
start by polling the 10G WIS status 3 register and the various error
count registers to find the defects and error counts for the previous
second, and it could determine the number of errors and whether the
second was an errored second, a severely errored second, or a
severely errored frame second in the same manner as above. The rest
of the process would simply be to increment the generalized non-
resetable counters without consideration of any inhibiting rules.
Heard Standards Track [Page 34]
RFC 3637 Ethernet WIS Objects September 2003
Contributors
Mike Ayers
1204 Knox Ave.
San Jose, CA 95122
USA
Phone: +1 408 857 6810
EMail: mike.ayers@earthling.net
John Flick
Hewlett-Packard Company
8000 Foothills Blvd. M/S 5557
Roseville, CA 95747-5557
USA
Phone: +1 916 785 4018
Fax: +1 916 785 1199
EMail: johnf@rose.hp.com
Kam Lam
Lucent Technologies
101 Crawfords Corner Road, Room 4C-616A
Holmdel, NJ 07733
USA
Phone: +1 732 949 8338
EMail: hklam@lucent.com
Kerry McDonald
Institute for Applied Supercomputing
California State University San Bernardino
EMail: kerry_mcd@hotmail.com
kmcdonal@csci.csusb.edu
Heard Standards Track [Page 35]
RFC 3637 Ethernet WIS Objects September 2003
K. C. Norseth
L-3 Communications
640 N. 2200 West.
Salt Lake City, Utah 84116-0850
USA
Phone: +1 801 594 2809
EMail: kenyon.c.norseth@L-3com.com
kcn@norseth.com
Kaj Tesink
Telcordia Technologies
331 Newman Springs Road
P.O. Box 7020
Red Bank, NJ 07701-7020
USA
Phone: +1 732 758 5254
EMail: kaj@research.telcordia.com
Editor's Address
C. M. Heard
600 Rainbow Dr. #141
Mountain View, CA 94041-2542
USA
Phone: +1 650 964 8391
EMail: heard@pobox.com
Heard Standards Track [Page 36]
RFC 3637 Ethernet WIS Objects September 2003
Full Copyright Statement
Copyright (C) The Internet Society (2003). All Rights Reserved.
This document and translations of it may be copied and furnished to
others, and derivative works that comment on or otherwise explain it
or assist in its implementation may be prepared, copied, published
and distributed, in whole or in part, without restriction of any
kind, provided that the above copyright notice and this paragraph are
included on all such copies and derivative works. However, this
document itself may not be modified in any way, such as by removing
the copyright notice or references to the Internet Society or other
Internet organizations, except as needed for the purpose of
developing Internet standards in which case the procedures for
copyrights defined in the Internet Standards process must be
followed, or as required to translate it into languages other than
English.
The limited permissions granted above are perpetual and will not be
revoked by the Internet Society or its successors or assignees.
This document and the information contained herein is provided on an
"AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Acknowledgement
Funding for the RFC Editor function is currently provided by the
Internet Society.
Heard Standards Track [Page 37]
|